Chemical Engineering Laboratory Design Services

Chemical engineering laboratories work with flammable solvents, reactive chemicals, and processes that can release heat or vapour. The design of a chemical engineering laboratory has to control exposure, manage the risk of fire and explosions, and still let engineers run repeatable, accurate work day to day. 

At iab-Lab, we design, install, and refurbish chemical engineering laboratories across the UK. From the first layout drawing to final commissioning, our design and consultancy, installation and refurbishment, and maintenance services cover the whole project. 

What are the Requirements for Designing a Chemical Engineering Laboratory?

A chemical engineering laboratory has to support process work at scale. The design needs focus on four key areas: containment and emergency provision for volatile chemicals, air management that keeps contaminants where they are generated, a layout built around process equipment, and utilities and building services that can adapt as processes change. 

Key design considerations include:

Containment, Extraction, and Emergency Equipment

Process work often heats, mixes, and transfers volatile solvents and reactive chemicals in large volumes, so vapour has to be captured at source. Extraction does this at each rig through walk-in fume cupboards (also called fume hoods), ventilated enclosures or extraction arms. 

In case of chemical exposure, emergency showers, and eyewash units should be within unobstructed reach of work areas, including around rigs. 

Chemical Storage and Segregation

Incompatible chemicals need physical separation so that a leak in one store cannot reach another, for example, acids from bases and flammable liquids from oxidisers. Working quantities should stay small at the bench, with bulk stock in a separate store and solvents in rated flammable-liquid cabinets.

HVAC and Air Management

Process equipment gives off heat and extraction removes large volumes of air, so a chemical engineering laboratory needs air management built into its design. HVAC systems match the air supplied to the air removed and also carry away excess heat, creating a stable working environment.

Layout and Space for Unit Operations

The equipment needed for process work determines the layout of the laboratory. Process rigs, distillation columns, heat exchangers and reactor systems all need space for staff to work comfortably and unobstructed routes to exits. Taller rigs may need a walk-in fume cupboard or ventilated enclosure. Space and layout planning helps ensure your chemical engineering laboratory can operate as efficiently as possible. 

Chemical-Resistant Flooring and Spill Containment

Chemical-resistant flooring that carries up the walls helps stop spills from reaching the building structure. Sealed joints, suitable drainage and bunding under rigs and drums also help contain spills so they can be cleaned up without wider damage. 

Modular Services and Utilities

Water, gas, and electricity need to be available wherever a rig is placed. Chemical engineering laboratories can be designed with modular service drops and overhead distribution that can reach each rig and keep floors clear. That lets team place rigs where the process needs them rather than where the pipes run. 

Flexibility for Changing Processes

Process development can change rig layout, so chemical engineering labs should be designed to allow for reconfiguration. Moveable benching, service gantries, mobile and static tables, and mobile extraction let teams move equipment without rebuilding services, with space capacity ready for the next rig.

Key Elements of Chemical Engineering Laboratory Designs

Furniture & Worktops

Chemical engineering labs need worktops and benching that can withstand regular contact with acids, solvents, and corrosive reagents without degrading.

We specify chemical-resistant surfaces such as epoxy resin, along with storage designed to keep incompatible substances physically separated.

Fume Extraction

Fume cupboards control airborne exposure at source in a chemical engineering lab, and their performance is governed by BS EN 14175.

We design and install fume extraction systems to meet these performance requirements, sized correctly for the substances you’re working with. 

HVAC Systems

Ventilation in a chemical engineering lab has to manage both general air quality and the risk of flammable vapour accumulating in specific zones. 

We design HVAC systems that deliver the air changes your process needs while working alongside your fume extraction and, where a DSEAR assessment classifies zones, the zoning. 

Regulatory Compliance

Tow key regulations apply to chemical engineering laboratories that handle hazardous or flammable substances: COSHH, which addresses health risk from hazardous substances, and DSEAR, which addresses the risk of fire and explosion from flammable or reactive materials. 

Our designs account for both from the outset. 

Architectural Design

Spatial planning matters as much as equipment selection in a chemical engineering lab. We consider hazard segregation, escape routes, and safe process flow at the design stage, so the layout supports safe working rather than being retrofitted around it. 

Special Gases

Many chemical engineering processes rely on a supply of process gases, which need to be piped, labelled, and isolated correctly. 

We design gas systems that keep supply lines clearly identifiable and safely routed through the laboratory. 

Mechanical & Electrical

Where DSEAR classification identifies a zone with the potential for an explosive atmosphere, electrical equipment and services within that zone need to be rated accordingly, for example, ATEX. An ATEX rating means equipment is tested and certified to work safely in potentially explosive atmospheres containing flammable gases and vapours. 

We specify and install mechanical and electrical services that meet this requirement as part of the lab’s wider design.

Cold Rooms

Some chemical engineering processes rely on temperature-controlled storage for reactive or unstable substances. 

We design cold rooms that hold the required temperature range while keeping stored materials properly segregated. 

Case Studies

Solenis UK Industries

SABIC

SGS Ellesmere Port

Chemical Engineering Laboratory Design & Refurbishment

At iab-Lab, we provide a range of expert services to help design, install, and maintain chemical engineering labs tailored to your requirements:  

Bespoke chemical engineering laboratories

We design layouts around any DSEAR area classification, chemical-resistant surfaces, and segregated storage for incompatible substances, so the space supports your process rather thar working against it. 

 

Fully-managed, turnkey installation & refurbishments

We manage fume cupboard commissioning, ventilation testing, and COSHH-compliant installation as standard, whether you’re fitting out a new laboratory or refurbishing an existing one. 

Future-proofed chemical engineering laboratory solutions

Chemical processes change. We build in the flexibility to adapt storage, extraction, and services as your requirements shift, backed by ongoing maintenance support. 

What our services include

  • In-depth consultation process with our expert team to help us understand your wishes and requirements.
  • Bespoke laboratory designs created by our designers using AutoCAD software.
  • Dedicated project manager to manage the entire process from concept to completion. 
  • Full management of subcontractors, site managers, and equipment installers. 
  • Turnkey lab installations built with compliance and health and safety in mind.
  • Option for ongoing maintenance contracts upon completion of your laboratory.

Accredited Chemical Engineering Laboratory Design

iab-Lab is ISO:9001 accredited and SafeContractor approved, giving you assurance in our quality management and site safety standards throughout your project. 

Why Choose iab-Lab?

  • 35+ years of experience 
  • Extensive experience designing, installing, and refurbishing labs for the education and learning sector
  • Fully bespoke design, consultancy, and installation service tailored to your requirements 
  • Dedicated point of contact throughout the entire process, from conception to completion
  • ISO9001 accredited and SafeContractor approved 
  • UK-wide service

Who We Work With

Chemical Engineering Laboratory Design: FAQs

What is the difference between COSHH and DSEAR?

COSHH covers health risks from hazardous substances, such as exposure through inhalation or skin contact. DSEAR, the Dangerous Substances and Explosive Atmospheres Regulations, covers the risk of fire and explosion from dangerous substances, and informs how a space is assessed and, where necessary, zoned. Many chemical engineering laboratories need to meet both, since the same chemicals can present both types of risk. 

Fume cupboards should meet BS EN 14175, which sets safety and performance requirements including face velocity, containment and testing. The correct specification depends on the substances in use and whether a conventional or dynamic low-flow cupboard is better fit for your process. 

Refurbishment is often possible, depending on the existing building and your process. We assess your existing space against DSEAR and COSHH requirements and identify what can be upgraded within the current footprint, whether that is fume extraction, storage or electrical services, rather than defaulting to a full rebuild. 

Timescales depend on the scale of the project and whether it is a new build or a refurbishment. Once we have consulted with you and understand the scope, we can give you a realistic timeline. 

Contact Us

Discuss your requirements with our expert team today using the details below, or fill out our contact form and we will get in touch

Get In Touch

Where to find us

Follow us on LinkedIn